Build Daily

Documents

August 12, 2017 18:07

SNIP 21-02-99 * - PARKING

click fraud protection

SNIP 21-02-99 * - Parking

Car System of normative documents in

building construction norms and rules of the Russian Federation

parking lot

SNIP 21-02-99

STATE COMMITTEE OF THE RUSSIAN FEDERATION
on construction and housing and communal complex

(GOSSTROY RUSSIA)

Moscow

2000

Preface 1 to develop the State enterprise "Center of methodology, regulation and standardization in construction» construction Committee of Russia with the participation of CNIISK.Kucherenko (SRC "Construction"), the Russian Interior Ministry and VNIIPO Giproavtotransa

2 INCLUDED Russian State Construction Committee Office tehnormirovaniya

3 adopted and put into effect on July 1, 2000 decision of Gosstroy of Russia on November 19, 1999 № 64

building regulations of the Russian Federation

parking lot

PARKINGS

Date of introduction 2000-07-01

1 SCOPE

These rules and regulations apply to buildings, structuresand space for parking (storage) vehicles regardless of ownership, and establish the basic provisions and requirements for space planning and design solutions, as well as the engineering equipment of buildings and their placement on the territory of the settlements.

The rules do not apply to buildings, structures and premises for parking (storage) for vehicles intended for the transport of explosives, poisonous, infectious and radioactive substances.

In these regulations apply the basic provisions and the general principles established by SNIP 21-01.

2 References

The present building codes references to the following documents:

SNIP 2.04.01-85 * Internal water supply and sewerage of buildings

SNIP 2.04.02-84 * Water.External networks and facilities

SNIP 2.04.05-91 * Heating, ventilation and air conditioning

SNIP 2.07.01-89 * City.Planning and construction of urban and rural settlements

SNIP 21-01-97 * Fire safety of buildings and structures

SNIP 23-05-95 Natural and artificial lighting

SNIP II-89-80 * Master plans of industrial enterprises

GOST 12.1.005-88 OSSS.General sanitary-hygienic requirements to the air of the working area

NPB 104-95 Design of people warning systems for fire in buildings and structures

NPB 105-95 Definition of categories of premises and buildings by explosion and fire hazard

NPB 110-99 list of buildings,structures, premises and equipment to be protected by automatic fire extinguishing and automatic fire alarm

NPB 250-97 Elevators for transporting fire units in buildings.General specifications

NPB 88-2001 "The fire-fighting and alarm.Norms and rules of designing

PPB 01-93 * Fire Safety Regulations in the Russian Federation

ONTP 01-91 ROSAVTOTRANS.General standards for technological design of road transport enterprises

GN 2.2.4 / 2.1.8.562-96 Russian Ministry of Health.Permissible noise levels in the workplace, in residential and public buildings and in residential areas

RD-3112199-98 Russian Ministry of Transport.Fire safety requirements for companies that operate vehicles on compressed (compressed) natural gas.

VSN 01-89 Minavtotransa RSFSR "Services Enterprises by car."

(Revised edition. Chg. Number 1).

3 DEFINITIONS

3.1 Car Parking (hereinafter - the parking lot) - the building, the construction (of the buildings, structures) or a special outdoor area intended only for storage (parking) vehicles.

3.2 Aboveground parking gated - car park with outdoor wall fence.

3.3 open-parking - parking without external wall enclosures.open parking is also considered such a structure that is open at least on two opposite sides greatest extent.Party is open, if the total area of ​​holes distributed on the side of not less than 50% of the outer surface of the side to each level (floor).

3.4 Parking with ramps (ramps) - car parks, which use a series of constantly rising (declining) number of floors or the connecting ramps between floors, which allow a car to move from its thrust and on the ground level.

3.5 Mechanized parking - parking, in which the transport vehicles in place (cell) carried out by special mechanized storage devices (without drivers).

4 ACCOMMODATION OF BUILDINGS AND FACILITIES

4.1 Placement of parking in the area of ​​urban and rural settlements, the size of their land and distance to other buildings and facilities should be provided to meet the requirements of SNiP 2.07.01 and SNiP II-89.

4.2 Parking lots can be located (subject to the requirements of these regulations) below and / or above ground level, consist of underground and above-ground parts (underground and above-ground floors, including with the use of the roof of the building), is attached to the buildings for other purposes or be integratedin them, including those located under the buildings in underground, basement, ground or lower floors above ground and placed on a specially equipped open area at ground level.

to the underground floors of parking places should be classified under the floors around the floor space below the level of the planning of land more than half the height of the premises.

Underground car parks may be placed also in the undeveloped area (under driveways, streets, squares, public gardens, lawns, etc.).

4.3 Parking is permitted to place in the annexe to the buildings of other functional purpose, except for the class of buildings of functional fire danger (SNIP 21-01) F 1.1, F 4.1 and F 5 categories A and B (on the airbag 105).

4.4 Parking is allowed to build in the building of another functional purpose I and II degrees of fire resistance class C0 and C1, except for buildings of classes F1.1, F4.1, F5 categories A and B. In the class F 1.4 car park of the building is allowed to embed whatever theirdegree of fire resistance.In buildings of class F 1.3 it is allowed to build in the parking lot of cars, except for parking lots open type, only with permanently fixed places for individual owners.

Under Building Class F 1.1, F 4.1 have a car park is not allowed.

(Revised edition. Chg. Number 1).

4.5 gated Parking for vehicles with engines running on compressed natural gas and liquefied petroleum gas, embedded in the building and other purposes to attach to them, and also have lower ground level is not allowed.

4.6 Fire distance from open areas (including shelter) for storage of cars up to buildings and constructions companies (. For car maintenance, industrial, agricultural, etc.) should be taken: a) to industrial buildings and facilities:

I,II and III degrees of fire resistance class C0 from walls without apertures - not standardized;

the same side wall with openings - not less than 9 m;

IV degree from the wall openings without fire resistance class C0 and C1 - not less than 6 m;

the same side wall with openings - not less than 12 m;

other degrees of fire resistance and classes of fire danger - not less than 15 m;

b) to administrative and residential buildings Enterprises:

I, II and III degrees of fire resistance class C0 - not less than 9 m;

other degrees of fire resistance and classes of fire danger - not less than 15 m

distance from the sites for the storage of vehicles to buildings and structures of I and II degrees of fire resistance class with the territory of the service stations of passenger cars with the number of positions is not more than 15 from the walls.with openings is not standardized.

4.7 Storage of vehicles for transportation of fuels and lubricants (POL) should, as a rule, provide for outdoors or in detached single-storey buildings not below II degree of fire resistance class C0.Allowed to attach to the car park are deaf fire wall of the 1st or 2nd type of industrial buildings I and II degrees of fire resistance of class C0 (other than buildings in categories A and B) if stored in a parking lot of cars with a total capacity of petroleum products transported less than 30 m3.

In open areas storage of cars for transportation of petroleum products should be provided in groups of not more than 50 cars and a total capacity of these materials is not more than 600 m3.The distance between such groups, as well as to sites for storage of other cars must be at least 12 m.

Distance for transportation of fuels and lubricants vehicle storage platforms to buildings and enterprise installations should take SNIP II-89 with regard to storage of flammable liquids, and to the administrativeand residential buildings of this enterprise - not less than 50 m

5 space-planning and design solutions

General requirements

5.1 Above-ground car park may provide a height of not more than 9 floors, underground -. not more than 5 underground floors.

5.2 Car parking can be:

with the participation of drivers - on ramps (ramps), or using freight elevators;

without driver involvement - mechanized devices.

5.3 In buildings of parking places is allowed include: office space for service and staff on duty (control

and cash points, dispatch, security), technical purposes (for technical equipment), sanitary facilities, storage room for customer baggage facilities for people with disabilities, andas public phones and a device to lift people.Their need for a composition and area are determined depending on design dimensions of the car park and its operation characteristics.

cabin dimensions of one of the passenger lifts should provide transportation of persons with disabilities who use wheelchairs.

5.4 categories of premises and buildings for storage of cars on the explosion and fire hazards should be determined in accordance with the requirements of the airbag 105.

Premises for storage of cars allowed to refer to categories B1 - B4, building parking lots of cars - Category B (exceptvehicles with engines running on compressed or liquefied gas).

5.5 carpark, are attached to the buildings for other purposes, they shall be separated from these buildings by fire walls Type 1.Parking

built into the building for other purposes, must have a degree of fire resistance of not less than the degree of fire resistance of buildings in which they are embedded, and separate from the premises (floors) of the building by fire walls and ceilings of the 1st type.

In buildings of class F 1.3 built-in parking is allowed to separate fire overlap Type 2, and the residential floors should be separated from the car park floor uninhabited (technical).

In buildings of class F 1.4 release of fire barriers built (adjoined) parking lot accommodating a passenger car owner of the house, is not regulated.In

built into the building for other purposes or adjoined to it car parks in order to prevent the spread of fire should be provided away from the openings to the bottom of the car park nearest the window openings of the building for other purposes not less than 4 m or fire filling window openings (except for buildings F 1.4).

(Revised edition. Chg. Number 1).

5.6 If necessary, the device as a part of the car park (under the design assignment) premises for the service trucks (MOT stations and TP, diagnosis and adjustment works, cleaning, etc.) should be provided for this purpose a separate building, room or group of rooms.These facilities may be provided in the car parks (except for parking lots open type and built-in residential buildings), and must be separated from the car park fire walls Type 2 and overlaps the 3rd type.Inputs and entrances to these areas should be isolated from the inputs and entrances to parking.

composition and floor space envisaged for the implementation of individual species or groups of maintenance and current repairs of cars, defined technological requirements of the relevant types of work, taking into account the requirements ONTP 01.

5.7 In premises of buildings, which are built car parks, should beprovided the noise level in accordance with the Russian Ministry of Health hygienic standards (GN 2.2.4 / 2.1.8.562).

5.8 In car parks built into the building for other purposes is not allowed, as a rule, provide for the common ordinary staircases and elevator shafts general.To ensure the functional link the car park and other purpose buildings outputs of elevator shafts and stairwells of parking cell, usually should be provided in the lobby of the main entrance of this building with the device on the car park floors tambour gateways of type 1 with air overpressure in case of fire.If necessary, the car park all messages from another destination floors of the building should provide smoke protection elevator shafts and stairwells of the building.

Message premises for storage of cars on the floor with another purpose premises (other than those specified in 5.3) or of an adjacent fire compartment is allowed through the vestibule gateway with air overpressure in case of fire or device deluge curtain over the opening from the car park.

(Revised edition. Chg. Number 1).

5.9 Placement of commercial premises, stalls, kiosks, stalls, etc.directly to the car storage areas is not allowed.

In areas storage of cars allowed to provide no more than two parking spaces for unloading (loading) of vehicles serving the company that owns the hotel.This should not be possible for the permanent storage of goods in the place of parking.

The storage spaces of cars belonging to citizens, to separate permanently fixed seats permitted to use a mesh fence of non-combustible materials.

(Revised edition. Chg. Number 1).

5.10 In multi-storey buildings of parking places for the movement of vehicles should include ramps (ramps), inclined intercommunication overlap or special lifts (mechanical device).

When using structures with a continuous spiral floor, each full turn should be considered as tier (floor).

For multi-storey car parks with a total number of mezzanine floors is defined as the number of mezzanine divided into two floor area is defined as the sum of two adjacent mezzanine.

5.11 Number of ramps and thus the number of necessary visits and entrances to car parks are determined depending on the number of cars, located on all floors except the first one (for underground parking - on all floors), taking into account the mode of parking use, the estimated traffic volume and planning solutionshis organization.

Typically, the type and number of ramps can be taken when the number of vehicles:

to 100 - a single-track ramp with appropriate alarm;

to 1000 - a two-lane ramp or two single-track rail;

over 1000 - two double-track rail.Entering (leaving) from the underground floors of parking cars across the storage area on the first or ground floors are not permitted.

(Revised edition. Chg. Number 1).

5.12 In parking places of the closed type common to all floors of the ramp must be separated (to be isolated) on each floor of the premises for the storage of cars by fire barriers, gates, and (or) tambour gateways with air overpressure in case of fire in accordance with Table 1.

Table 1

type parking

Fire resistance walling ramp (fire barriers), min, not less

requirements necessary device tambour gateway

walls

gate