The chimney for a bath - features of the device and installation

click fraud protection

Select pipe for bath

277 smoke - pipe - for - bath - 26593

second type of structures - radical, where the chimney is mounted on the furnace foundation.Its advantage is security disadvantage - on a large scale.However, many owners prefer the push-type baths, as this option is less costly, and such a structure is easy to install, without recourse to experts.

277 smoke - pipe - for - bath - 27868

iron chimney installation process consists of the following stages:

  1. Creating a foundation under the chimney
  2. Arrangement interior and attic areas chimney
  3. equipment chimney entry points into the attic and roof
  4. upper portion of the chimney decoration.

277 smoke - pipe - for - bath - 37655

How to install pipe in the bath - the creation of a base

Dymoprovod push-type is attached to a special allotment, built-in fireplace enclosure.Withdrawal must be made of heat-resistant material.Typically this pipe made of cast iron or ceramics, preferably refractory stainless steel and acid.One end of it is in the furnace area, the second - on the level of the body.To this end discharge chimney is attached portion that extends inside the steam room.

Most often it is placed in a steam generator removal zone.This is important for the reason that in the course of removal from the furnace output not only the products of combustion, and a heat required for heating the stones.

277 smoke - pipe - for - bath - 57549

Root chimney for a bath looks like a pillar, built of bricks or blocks.Withdrawal from the furnace is connected to dymoprovodu using the so-called sleeves.Supports for this design is the foundation of the furnace.

Root chimney permeates all space from the ground to the roof.Self-improvement such dymoprovoda very difficult.This is labor-intensive brick or block masonry.Also, a significant drawback of the brick chimney is that it needs more frequent cleaning.

277 smoke - pipe - for - bath - 74167

Arrangement interior and attic pipe sections for the bath

During the internal hardware and attic elements need to remember a few details.Internal dymoprovod should be removable and collapsible, so it will be easy to replace in case of burn-out.Also, the pipe inside the steam room must be multi-layered, and consist of a core, a heat insulator and housing.

Attic station flue must be warmed using a heat-resistant heat insulation, for example, foil insulating.

for mounting interior and attic areas of the chimney should be phased out the following procedures:

  • The attic ceiling to make a hole through which dymoprovod come to the attic;
  • Through this opening to enter the inner portion of the chimney, the edge of which shall protrude from the ceiling level;
  • equip in the attic area of ​​the node that combines an internal chimney and attic;
  • make a hole in the roof, through which the flue will extend beyond the building.Conclusion on the roof is best done through the skate;
  • through the hole in the roof attic implement land chimney and connect it with a knot.

277 smoke - pipe - for - bath - 79742

equipment entry point for bath tubes

chimney for a bath "cuts" the attic and roof slab.The holes need to be sure to isolate, because through the gaps, hot air and steam will leave the pair separation.

To obtain an entry point in the attic ceiling from the pair "window" closes a sheet of heat-resistant material with a cut to the pipe.This sheet is mounted to overlap with screws.Removing any direction from the attic you can paint over clay.

«window» is the inner side roof sealed same sheet with a hole for the channel, as in the case of an attic.On the outer side of the "window" is closed by means of a flat-top cornice.

on top of chimney that extends outside of the building, is to wear a kind of cap with visor.This protects the inside of the chimney and the hole in the roof of the precipitation.

Once the entry points in the ceiling and construction of the upper part of the chimney for a bath is considered to be ready for operation.

work, we have described in this article do not require much effort and material costs.However, it is important to make calculations and mount design.On this depends the safety and comfort of relaxing in the bath.