Build Daily

Electrical And Lighting

August 12, 2017 18:06

Step by step chart to connect the indirect heating boiler

click fraud protection

centralized hot water - more myth than reality.In most communities the benefit of civilization is no longer to be available for many years.But there is a great alternative - water heaters, boilers, they are the same.On sale are available many models of such units: flow, storage, electric, gas, etc.

Step boiler wiring diagram indirect heating

And if you connect the gas vodogreek must deal specially trained people, the electric heater can be connected to the water on their own.The guidance will help you thoroughly understand all the subtleties and nuances of the event.

Water heater installation diagram

heater installation

circuit Preparing the connection heater

Article Contents

  • 1 Preparing the connection heater
  • 2 set for
  • 3 To install and connect the boiler
  • 4 Nuances connect the boiler to the pipes of different materials
    • 4.1 Connecting to polypropylene tubes
    • 4.2 connection PVC pipes
    • 4.3 connection to steel pipes
  • 5 Useful tips from professionals
  • 6 Brief important: safety valve
Selection of boiler volume

Selection of boiler volume

Choose a location for the unit.It is better to have free access to all the connecting elements of the system - so it will be easier to carry out maintenance of the equipment and carry out repairs with the appearance of such a need.

Example of installation of the boiler in the bathroom

Installation example boiler in the bathroom

If you select the cumulative model heater, make sure that the wall can withstand the weight of the water.Subtle interior walls and plasterboard walls with this problem is definitely not right.

Example of installation of the boiler on the main wall bathroom

Installation example on the main wall of the boiler bathroom

Install water heater in close proximity to water pipes - so you need to save yourself from laying additional infrastructure.Therefore, the ideal place for the installation of the boiler is a bathroom.

Boiler in the bathroom

Boiler in the bathroom

Important!The heating elements are electric boilers have a high capacity.On average, it is about 2 kW.That in future no problems with the wiring, experts recommend to connect this kind of equipment directly to the distribution box, using copper wire as possible with a large cross section.The closer to the shield is installed boiler, the need to use less wire.Understand and this moment.

Driving cylinder power selection

scheme selection power cylinder

selecting a place for installation of the heater, proceed to the preparation of tools and related accessories.

set for

  1. level.
  2. Roulette or ruler.
  3. Punch.You can replace the impact drill.
  4. pliers.
  5. wrench.
  6. Tees fittings.They will carry out the sidebar in the water pipes.
  7. stopcock.
  8. sealing tape.Needed for sealing the connecting elements.You can replace a tow or a special paste.
  9. Flexible connecting hoses.Through them will be taken and discharged water.
  10. more pipes.Buy if necessary.Be sure to check with the seller, can the pipe you have selected to withstand operation in future conditions.

To install and connect the boiler

To install and connect the boiler

To install and connect the boiler

Installation Recommendations

Installation recommendations

ready to install the boiler.Put the water heater to the site of his future placement on the wall.The distance between the tank and the ceiling should not be less than 100 mm, otherwise you will not be able to hang the unit on the fasteners.

to fasteners

Fastening anchor carried on stud bolts , the diameter and length selected according to the wall material and the volume of the tank

Requirements Fixing is made on anchoring spacer screws, the diameter and length of which is selected depending on the wall material and the volume of the tank

cylinder capacity l approximate load on pulling kg wall material Recommended bolt diameter mm Recommended bolt length, see
30-50 liters 15-25 Concrete 6-8 6-8
30-50 l 15-25 brick / cinder block 8-10 8-10
80-100 l 25-35 Concrete 8-10 8-10
80-100 l 25-35 brick / cinder block 10-12 10-12
150-200 liters 45-60 Concrete 10-12 8-12
150-200 liters 45-60 brick / cinder block 12-14 12-15

Schedule with a marker or pencil attachment points.Do this carefully.If the tank is big and heavy, invite the assistant.

marking

Layout

Drill holes and screw fasteners.Usually they are included with the tank.If the fasteners are not available, buy them separately.Suit steel hooks.

The holes drilled on the markup

holes drilled at the marked

Twist- hooks to the desired depth

twists hooks to the desired depth

Hook screwed

hook screwed

Mounting vertical boiler

mount vertical boiler

hung boiler

hung boiler

Before installing the water heater, make sure the integrity of thethreaded connections for water inlet and outlet.Experts note that the hoses and the relief valve often unscrewed 1-2 turns.If you too have found such a defect, carefully drive out the thread die of half an inch.Screw the valve or hose force is not necessary.

Replace the boiler 2 separate overlapping crane.Examine the appearance of the output thread: blue must be connected to the cold water through the red will leave the heated liquid.Apply sealing tape, screw the relief valve on the cold water inlet and connect to the water supply system, a convenient way (using pipe or hose).Experts strongly recommend the use of flexible hoses, especially in apartments.

The wall walled muffled MRI ( Coupling with thread Female )

The wall walled muffled MRI (Coupling with thread Female)

Twisted cap

Twisted cap

Prepare fittings for installation

Prepare fittings for installation.1.Perehody with thread on the thread ¾ ½.
2.Udliniteli thread.
3.Krany.

First cheat transitions and extensions

first screwed into the transitions and extensions

Use laths

Use laths

Screw- thread fittings and extension cord

is screwed fittings and extension cord thread

Linen thread is wound on the cylinder output , coated with a paste

Drum linen to the threads of the heater output, daubed paste

Screw tees

Screw tees

The tees are screwed taps to drain the water from the water heater

The tees Screwing taps to drain the water from the water heater

Right valve used to drain .Left - for supplying air to the tank

Right valve used to drain.Left - the air supply to the tank

Install a safety valve

Install a safety valve

Safety valve

safety valve.A - the water flow direction.
B - Connection to the drainage system.
C - Handle water drain

Hose nut - fitting

hose nut-fitting

Connection hose cold water

Connection hose cold water

Connect the second hose

Connect the second hose

Apply cold water to the boiler.At the same time, open the valve on the hot water - so you bleed air from the system.

At the end will only have to connect the boiler to electricity.

Rated wire size needed to connect the water heater

Rated conductor cross-section required for connecting

water heater is not recommended to simply connect the heater to the nearest power outlet through a cheap power strip.Although in practice most do so, such an option connection is not secure and correct.Once selected, the responsibility for possible trouble will lie to you.

Cut the cord to the desired length .Threading it through the hole in the lid of the boiler

cut the cord to the desired length.Threading it through the hole in the lid of the boiler

Remove the insulation from the ends

Remove the insulation from the ends of

Connect the wires to the boiler .The yellow- green wire to the body of the boiler .Blue and brown terminals thermostat

Connect the wires to the boiler.The yellow-green wire to the body of the boiler.Blue and brown terminals thermostat.The terminals on the thermostat marked: Left zero, the right line or phase

Put the insulation and close the lid

Put the insulation and close the lid

tank is recommended to connect a separate branch of the switch box.A branch need to be equipped with an automatic shutdown.Recommended machine capacity - 16A.To connect to the mains supply must be removed with a wire heater factory and have instead a new cable from the panel.For wiring, use a three-wire copper cable 2.5 mm2.

heater necessarily need to be grounded.The lack of protective earth faces a lot of trouble.If light "bite" shock while taking a shower you can still survive, the total wiring failure and fire - a situation far more tragic.

Wiring of the boiler to the shield

scheme to connect the boiler to the shield

tank Ground follow straight to the distribution switchboard.If you do not possess the necessary skills for this, have a qualified electrician.To ground is also recommended to use copper wire.

Nuances connect the boiler to the pipes of different materials

Depending on the material of manufacture of water pipes, the order of tapping water heater will be somewhat different.Check out the existing nuances, to get the job done most efficiently.

Connecting to polypropylene tubes

Connecting to a polypropylene pipes

Connecting to polypropylene tubes

If the pipe is not hidden in the wall connecting the boiler will not have any difficulties.All work is to ensure that you cut the water supply pipe in the right places (depending on the installation height of the tank), soldered into the prepared hole tees, and have them spend the pipe to the heater.To connect with cranes use a conventional clutch.

Clutches

Clutches

little more time and effort you spend on a connection, if the pipes embedded in the wall.In this situation the procedure is as follows:

  • opened pipe;
  • carried Box scheme discussed above;
  • output connections;
  • pipe closed back.

connections are made via tees and detachable sleeves.Wait until hardening soldered joints, connect the connectors and connect the boiler to the water supply.

Pike polypropylene pipes

Pike polypropylene pipes

Connection PVC Pipes

technology does not allow to mount plastic pipes hidden way, with a hole so no special problems will not arise.

Connection to PVC Pipes

Connection PVC Pipes

is enough to cut the pipe, insert tees and bring water to the elements vodogreyke.This Box is complete.

connection to steel pipes

most complicated case.In this case, the tank will be supplied through the kitchen faucet connections.Each outlet on the need to wear a tee - it will connect the boiler and the kitchen faucet to a single tube without slicing thread.

Useful tips from professionals

There is some important nuances, without the knowledge of and compliance with which the boiler water supply connection is incorrect.You should know that the hot water system do not need to complement any additional elements, except shut-off valve.It is installed on the boiler tube.

Socket as cold water is installed after the preliminary mounting tee.Crane for removing excess water from the water heater cold cuts in the side outlet of the splitter.It is also connected to the tee of the return valve and shut-off valve.Last connected to the water supply.

How to drain the water from the water heater

How to drain the water from the water heater

When connecting the tank to the water shall be prohibited to do the following:

  • open the protective window when the heater;
  • feel empty boiler.Pre-need to fill the tank with water, otherwise the heater may burn;
  • drained, without turning off the pre-heater;
  • complement vodogreyku parts from other boilers.The exception is the same model as well as tanks with compatible parts.

Brief important: safety valve

Safety valve for water heater

safety valve for the water heater

deserves a separate section of an element of the system as a safety valve.It eliminates the possibility of leaving fluid in the return water, and promotes the normalization of pressure in the system by discharging excess water during its heating.

important caveat: Do not install a check valve in place of safety.Because of this temperature switch may malfunction, causing the boiler to explode.

Installing the safety valve is performed in place of cold water inlet to the heater.Connectivity technology prohibits placing the locking elements between the entrance to the tank and safety valve.

Important!Keep an eye on the state of the valve during the operation of the tank.If the brass device for a long time remains dry, this may indicate a malfunction.The failed unit must be replaced as soon as possible.

Now you can connect the heater to the water supply in compliance with all the requirements and nuances of technology.This is a great opportunity to save on plumbing services and to keep the whole process under the personal supervision.

The recommended amount of water heater

Recommended volume boiler

Successful work!

Video - How to connect the indirect heating boiler to the water

instagram viewer