Build Daily

Floor

August 12, 2017 18:06

Installation of electric floor heating with their own hands under the laminate

electrically heated floor creates a unique atmosphere of comfort in any room of your home.It can be used in different types of rooms, such as bathrooms or in children.In addition, electric heated floor can be covered with any type of finishing floor coverings, for example, is extremely popular in our country laminate.

Warm floor with their hands

Warm floor with their hands

warm floor under the laminate is very suitable, for example, for a child's room.Your child will be able to play on the floor all year round and you do not have to lay extra mats or mats.

Heated floor under the laminate mounted in the bedroom will allow you to start your day with the most pleasant sensations, morning meeting with a feeling of tender warmth beneath his bare feet.

Mounting heated floor under the laminate you may well spend their own hands, without the involvement of master stroyteley.Consider the algorithm for its installation.

Required tools and materials:

Actually the electric heated floor.

For installation, we need:

Actually the electric heated floor.

Actually the electric heated floor.

In the box you will find the user manual, electric roll heated floor, electrical connection cables and insulation kit from bitumen to protect the terminals.

Set a warm floor

Kit floor heating

Also, you need to purchase a thermostat

Thermostat - Photo

Thermostat - Photo

heat-reflective film to the heated floor.It can be distinguished by the characteristic foil layer.

heat-reflecting film for heated floor - photo

heat-reflecting film for heated floor - photo

also be reserved on the basis of polyethylene film or the substrate under a laminate is compatible with heated floors, duct tape, mounting the knife, pliers and a screwdriver.

preparatory work

expect the area of ​​the floor surface, the part on which we will lay the heating film.Do not place the film under fixed lower- priced furnishings.

We expect the floor surface area

Racschityvaem floor surface area

You can make a drawing of your future floor heating on graph paper.

ahead in what place will be located the thermostat of your hot sex.

Location thermostat for floor heating

Location thermostat for underfloor heating

Puts heat reflective material

to enhance your space insulation is placed on the floor of the thermally reflective material.

Placement of thermally insulating material

Accommodation insulating material

fix a heat reflective material with a stapler or a metallized tape.

Fixing insulation

Mount

insulation In any case, the strip heat-reflecting material between them must also seal the tape.

Fixing insulation material between them

Fixing insulation material between them

Here is the floor surface is covered with heat-reflecting material, held together with tape.

The floor surface at the moment

floor surface at the moment

Laying electric underfloor heating

spreads shrink film according to the developed scheme of installation.Please note that the copper strip on the Thermal Film has to be at the bottom.

Spreads shrink film on the floor surface

spreads shrink film on the surface of the floor

If necessary, cut the pieces of imaging film at the locations specified by the manufacturer.

Pay attention to how to cut shrink film

Notice how to cut the shrink film

Placing the cut sheets according to the developed scheme ukaldki.

Photo - placing the heating elements warm floor

Photo - placing the heating elements warm floor

Connect insulation

Now fuser sheets, spread out on the floor to be connected to electrical cables and insulation to hold the locations of electrical contacts.

contacts Insulation heated electric underfloor heating is a special bituminous stickers that can be divided into two parts.

Isolation of contacts

contacts Insulation

us isolate using bitumen label the place where you made the cut copper bus.

Isolating contacts - photos

Isolating contacts - photos

Please note that the insulation must be superimposed on the entire length of the cut to close the copper surface and contacts leading to the elements of the dark material on a heated - electric floor.

Close insulation using a copper surface and all contacts

closed by the insulation all the copper surface and contacts

Placing the contacts in the places where you want in the future to connect the wires of electric power.

Connect the wires of the electric power

Attach the wires of electric power

contact our disposal so that one side of the layer is inside the heating film.The second side of the contact in this case must be placed poverhpolosy copper foil.

Pin

Pin

Using pliers firmly stifle contact, ensuring its secure fit.

We fix contacts

fix a contact

fix an electric heated floor layers together with duct tape, and attach the strip to a heat-reflective material.Eliminates the possibility of shifting layers.

We fix tape layers

fix a tape layers

We embed the stripped end of the electrical cable to the corresponding contact hole.

Attach the power supply cable

Attach the power cord

fix a wire in the opening of contact with a pair of pliers.

We fix the wires in the contact hole with the hole in the wire passatizhey.Fiksiruem contact with a pair of pliers .

fix a wire in the opening of contact with a pair of pliers.

We fix all the places connection of wiring to electrically heated floor using bituminous labels.

Attach the power supply cable to the wire

Attach the power supply cable to the wire

Connect

thermostat With thermostat, we can significantly save energy consumed by your warm floor, including his only at that time and at that point, what you need.

supplied with your electric heated floor typically includes a temperature sensor.Place it under the film on the heating element of black.

Temperature Sensor Installation of a film

temperature sensor Installation for film

Fix the sensor on the tape segment izolyatsionnnoy stickers from bitumen.

To temperature sensor did not break the surface of the final flooring - make him a slot in the thermally reflective layer material.

Make a cut in the insulation material

Make a cut in the insulation material

also to ensure the evenness of the laminate making cuts in a layer of heat-reflecting material under the contacts and wires.

cutouts in the insulating layer can be made by wire bundles.

Make cutouts for electric cable

Make cutouts for electric cable

wires placed in recesses must be secured with tape.

We fix the wires with tape

fix a wire tape

mounted on the wall at the selected location mounting the temperature control panel.

Set the temperature control panel

Set the thermostat panel

marked on the thermostat according to the wiring diagram fix the connecting wires.

Connect wires - photo

Connect wires - photo

powerful systems for electric heated floor is recommended to connect the thermostat wiring through a separate circuit breaker.

Connect the circuit breaker

Connect breaker

Verifying and testing the heated floor system.

Turn the thermostat of the heated floor system.

Turn the thermostat

Turn thermostat

produce heat checks each strip laid electric warm floor.

Check the electric floor heating on the performance

Checking electric underfloor heating on the performance

particularly carefully inspect the joints.They do not have spark and overly warm.

deploy on the floor surface polyethylene captivity.You can replace it with any substrate under the laminate board, which is allowed to use in conjunction with heated floors.

Then we laid on a plastic film

further laid on the polyethylene film

Proceed to finish laying the flooring -naprimer laminate boards.

Laying laminate on floor heating

Laying laminate flooring on warm

Be careful to assemble laminate boards with great care so as not to cause damage to the laid floor is electrically heated.

Video - electric warm floor under the laminate

instagram viewer