Noise sewer pipes

click fraud protection

causes of noise

  1. width of the pipe wall - the most noisy pipes are low
  2. Building material wall thickness of which made communications - polymer pipes practically do not absorb noise, which is not the iron.
  3. Placing tubes relative to the walls - most advantageous is the design of sewage separately from residential premises in special mines.
  4. material that is used in the performance of insulation - the use of foam, good sound conduction, not recommended

The causes of the noise

Types of insulation pipes

  • Using a specially designed pipe.In today's market presents high-tech products from the polymer-rich mineral materials having a high density, in consequence of that they have a high sound absorption capacity.
  • Application special insulation.Running through the sewer pipe insulation wrap special materials around pipes properly schumoizoliruya pipes, as well as used as a thermal insulation.

Types of insulation pipes

Species insulating materials

Variety of insulating materials

  1. The use of foamed PE as not only sound-absorbing, heat-insulating material and is very effective in view of its high porosity.Just do not allow moisture to condense on the surface of the pipe, which prevents the appearance of mold and mildew

    necessary to choose insulation which foreign film differs high durability, enabling it to be used for a long time.

  2. Special electrical tape with sound insulation effect is wound on the pipe in several layers, maintaining most of its snug fit to the surface.

    effectiveness of a variety of tape depends on the insulating capabilities that can be found with the markings on the packaging.

  3. Roll soundproofing is a little old-fashioned way and is carried out by winding the material around the pipe and fixing ties or wire

Variety of insulating materials

To enhance the sound insulation is necessary to achieve maximum contact with the surface of the material without the formation of the air layer.

insulation outer sewage

For warming of external gutter systems using different materials, used mostly following:

  • mineral or glass wool sheets that wrap pipes of considerable size
  • Cases for pipes that are placed on communication, afterwhich they are bonded
  • foam shell, which is installed on the tube and fixed thanks to its special design

Insulation of the outer sewerage

building materials used as insulation, polyethylene foam are often basalt sheets and glass fiber, are usually used for neuglublennyh sewer networks, mineral woolto withstand high temperatures up to 750 degrees, as well as rubber, with insulation that is achieved the largest leaks.

Noise sewer pipes, in addition to thermal insulation, is an extremely important part of the installation, dismantling, repair and finishing of the network, should be performed at a high level.From the quality of insulation depends on the effectiveness and durability of the system.