Build Daily

Engineering Systems

August 12, 2017 18:08

Connection to the sewer toilet

click fraud protection

basic elements for assembly work

When a connection to the sewer sink drainage system should be applied plastic releases, crimped or eccentric lip system, as well as fans of the pipelines.To use the sewage pipes when installing the toilet, you must observe the following rules:

  • Cropping such tubes is prohibited.
  • Any change their geometric shape are not permitted.

It must be remembered that the pleated cuffs are opposed to the eccentric.The first embodiment can be bent at different angles, as well as on the length and the second embodiment rotates only the cuff axially offset and thus deviations from different pipes are connected coaxially.

When corrugated cuffs used to connect the installation, it helps to avoid problem areas, if any.Also, such a compound is used in conjunction with a sewage system as it has different sockets.

How to connect the toilet to the sewer

Compound corrugated pipes

basic connection procedure consists of:

  1. To use the toilet in the drain pipe to be inserted corrugation and do not forget this is the place to spread silicone gel.
  2. sewer sink must be connected to the pipe by means of connection with the second part of the sleeve.To check for serviceability, it is necessary to fill the tank with water and drain installation.
  3. toilet must be attached to the floor of the room with dowels.
  4. in the marked locations necessary to make the holes for fastening the installation and fix the anchors.
  5. There securing sewer sink in the intended place with the corrugated pipe, which in turn lubricated akriplastom.If the test, do not leak, then it is possible to attach all.

connect the toilet to the sewer 1

toilet connection without corrugated pipes

To make the connection of the toilet to the sewer without corrugated pipes, remember this:

uses a special tube, which has the name as the adapter or sewage pipes.We can distinguish three types of connection:

  • Diagon release.At the moment, such a connection is overdue, as is used in the floor, but in the past it was very common.
  • Vertical release.This connection is performed at an angle of 90 degrees.
  • Horizontal outlet.Installation of such a plan is at an angle of 30-40 degrees to the wall.

connect the toilet to the sewer 3

Connection toilet with a vertical release

In this connection the outlet is located in the bottom and the discharge pipe to the siphon located in the sewer sink.With this arrangement, the setting can be positioned at different angles.For proper installation is necessary: ​​

  1. After will be exhibited all the marks, it is necessary to make the establishment of a screw flange, which should be a lock.
  2. drain pipe should be placed in the center of the edge.
  3. sewer sink must be installed on the flange, and outlet must be tightly pressed against the drain pipe.

Connection toilet with a horizontal issue

This installation method is the most popular, since its use is attached to the toilet bowl is definitely the chosen wall.The installation release located in the rear of the toilet bowl.With the help of a special seal to the sewer pipe is attached to the release.

must be remembered that if the system has a direct issue, then its accession need to use screws and wall plugs.Samokreplenie toilet needs to be done very carefully, do not need much to tighten the screws as this may damage the ramp toilet.

connection with an oblique descent

toilet to the sewer connection can occur via an oblique connection that has the technological installation processes:

  • Release sewer installations should be covered by a particular paint that is mixed with linseed oil.
  • resin strand is wound on top of which an offshoot of 0.5 cm should be free location.
  • Tar strand should be covered with paint.
  • Installation Installation is done by fixing the process in the socket drainage pipe.

Connect the toilet to the sewer 5

instagram viewer