Wiring differential machine

We have already discussed with you how to connect the Emergency circuit breakers with their own hands.The event is not difficult, the main thing is correct to consider where to install the device in the control panel and select the most appropriate product specifications for power.Next, we elaborate on the first point and show you some of the differential circuits connecting the machine to 220 V and 380 V.

Contents:
  • single phase 220 V three-phase network
  • 380
  • Without grounding

single phase 220 V

in apartments and private homes, often using an outdated version of the wiring - one phase.In this case, the rated voltage is 220 V, so you must use a two-pole product.As regards wiring diagrams Emergency circuit breakers, it can be presented in two versions.The first - when the protection is set only after the electricity, serving the whole house wiring.

Driving with the opening safety device

In this case, when triggered and automatic cut-out will be harder to find a way out the cause of the failure, it is desirable to give preference to the second, more reliable option.

correct wiring diagram Emergency circuit breakers in a single-phase network:

Individual service of each group

As you can see, for each group of wires mounted on a separate article.Emergency circuit breakers If one works, the other will continue to function.

three-phase network of 380

The only important difference between the 3-phase network lies in the fact that instead of one phase conductor on the input provided at once three phases: L1, L2, L3.In this case, you must use a 4-pole Emergency circuit breakers on 380V, wiring diagram which will look like this:

Wiring Emergency circuit breakers in the three-phase network

This option can be used in a new house, or rather cottage, which must withstand high current load on the electrical equipment.Also, this option is sometimes used when installing wiring in the garage, becausehere can be applied strong welding machines, compressors and other electrical equipment.

Without grounding

All previous schemes differential machine connections were with the ground, now I would like to provide an outdated model, which uses a two-wire 220V network.

Connect Emergency circuit breakers without land should be as follows:

Without PE- protection

This method of wiring can be seen in old houses panel type.It is extremely safe and, therefore, recommend that you replace the wiring in the building to the new, with grounding.

Worth also view existing connectivity options in the form of reviews:

YouTube Preview
YouTube Preview
YouTube Preview

That's all that I wanted to talk about this topic.We advise you to use differential machines only on the popular manufacturers: abb, legrand (LeGrand), IEK and Schneider electric, that protection lasts for a long time, and most importantly - on the conscience.