The joint between the laminate and tile - a close up it nicely ?

click fraud protection

Piling of tile and laminate - in some cases, face it?

This zoning can be done with the use of a small hill - podiums.In this case, docking tiles (it is usually laid flooring in the kitchen work area) and in the dining area of ​​the laminate is carried out "natural" way.Several complex organic perform the migration into the laminate tiles on the same level.

This can happen not only in the kitchen-dining room.Coanda heterogeneous floor covering is justified also in the hallway and the hallway. Obviously, the more resistant to abrasion tiles is best to clean and less afraid of scratches from sharp heels. seems reasonable and practical ceramic floor in the hallway with the transition into the coating laminate corridor leading to the living area.

experience quite different compounds on the properties of materials for flooring provides a total gain in strength, service life and practicality of use.An important factor may be cost savings and taking into account the operation of the floor areas.There are quite a number of ways of practical implementation of such a transition.

combination of tile and laminate can be carried out, ranging from simple prirezki on the border and form joint flooring with fastening to the sub-floor or the ground, to the use of prefabricated buildings with special nozzles and fixtures.The use of each as a whole will determine not only the visual appeal and overall impression of the floor, but also the time, such as the floor will last without repairs are required.

joint between the laminate and tile - treatment options

One-level joints between tile and laminate are often performed with the thresholds, thresholds or moldings.Pictures are typically used for wood, aluminum or different kinds of plastics.Certainly, from the point of view of abrasion resistance and durability of aluminum leads here.But it does not always fit into the overall application design decision of all floor coverings.

nut, often, can be straight, but sometimes they are given a curved shape.Simply and securely fastened them to the surface of the subfloor on dowels or screws.Of course, this can be achieved in that the height of the nut is flush with the height of the coatings on both of its sides.

However, the advantage of this method of joining is that if some of the pieces will be slightly higher, the nut will be a step transition and smooth out such irregularities, making it more natural and not so noticeable.

widely used tiling and laminate butt.This method of connection without additional materials and transition elements requires careful execution.Fixing coatings on the rough floor should be a single level and carried out in compliance with the rules of fasteners, particularly at the point of junction.

Pre-need to perform measurement and prirezku interface using prefabricated templates.This rule is always observed for the complex shape boundaries of the zones.The resulting connecting seam is performed with careful trowel.No nut can not you arrange a curved seam.

options like join tile and laminate can be the use of construction foam, silicone sealants and mastics.They enable the implementation of any form of joints of different widths or depths.In addition, the existing range ensures accurate selection of the desired color combination.

Unfortunately, this technique does not provide mobile performance or partial repair of the floor pieces.When you need, you need to dismantle the entire joint.Another disadvantage is the need for experience with similar materials as well as an excessive amount of material is difficult to remove from the surface of the coating, and the lack does not provide a reliable fastening of the joint.

of sufficient quality for this dock can be considered the use of cork compensator.It effectively provides a combination of tile and laminate on one surface, forming a beautiful and neat joint.Its use is associated with increased requirements to implement the joint - it should be uniform across the width and depth.

How to connect tile and laminate - particularly workflow

Before you dock the tile and laminate flooring, it is necessary to present the end result, knowing that the quality of the performance of a particular type of interfacing, ultimately, depends on how muchIt will serve as a floor.In general, considering the sequence of work, you need to make a start on the existing tiles, laminate, chosen method of docking, as it is defined in metiz need for fasteners, adhesive compositions or sealants.

Preparation besperehodnoy step of the podium or requires that the coating formed a single level floor.The ideal option for this would be the same thickness of the tile and laminate.When selecting coatings need to be aware of this.When planning the joint space, it is best to choose accommodation in the center of the door opening or arched.Enough of such joint organically looks in the central part of the room.The estimated width of the gap between the coating should be less than five millimeters.

The best and easiest way how to connect the tiles and laminate, is the nut, both in ease of mounting methods, and as far as possible to hide minor irregularities and a small difference in height resulting floor areas.Apply angular sills and floor.For straight sections of joints should be fine mounting straight.

For complex curved shapes specific thresholds used docking.For example, with a perforated base and the ability to impart a desired bending shape.Some thresholds already have mounting holes in the center of the surface, some are designed for hiding fixing by snapping on a flat, somewhat protruding, head of the screw.This implies the need for pre-selection of fastening elements corresponding to the type of nut.

instagram viewer