Driving venting water drain in a private house

Driving venting water drain in a private house

For any sewer ventilation schemes in the private house of the main task is to protect the home from the penetration of odors, which can severely damage the life of all residents.

It is known that an increase in temperature on the street, a strong wind, as well as many other factors lead to the fact that organic begins to actively decompose, thereby producing rather unpleasant odor, which becomes a serious problem if a private home is not equipped with an efficient drainage system.

addition, sewerage system specifically intertwined with water and heating systems, which in turn also in some instances lead to the formation of various stench.

device riser, other elements of the sewerage system, as well as heating and water supply systems at the design stage should provide the equipment in a private house some systems that are responsible for the removal of the atmosphere of stench.

In any case, the sewage ventilation in a private home should be equipped according to the rules and in accordance with generally accepted standards.

course, layout and ventilation device in a private house has its own specific characteristics, but with the right approach they can be rehabilitated in a short time frame with his hands.

Contents:

  • Features
  • ventilation systems design nuances
  • Arrangement vacuum valve
  • Features ventilation

Features ventilation

Design and installation of sewer ventilation is a must for any private home.

That it becomes a barrier to the spread of all sorts of unpleasant odors emanating from the riser sewer, water and heating.

Each riser in a private home ventilation should be possible, in addition, in this case the circuit may be provided in which all the struts are combined into a common ventilation system.sewerage scheme

Currently, in order to duly equip a private home sewer riser ventilation system, it is necessary to adhere to certain rules.

First of all, from the exhaust pipe must rise above the roof of the structure is not less than one meter.

In the case where the sewage system, water supply, heating and have a common ventilation pipe, use of the same diameter.

addition, the output portion of the vent pipe should not make the cap assembly, since in winter condensation accumulated on it can lead to the formation of ice plugs.

It should be remembered that the sewer ventilation in a private home in any case should not be combined with both the chimney and the general ventilation system.

not recommended to place the ventilation output coming from the riser, at a distance closer than four meters from the windows and balconies of a house.

also not advisable to carry out installation of ventilation outlet in the vicinity of the eaves of the roof, as if gathering in the winter snow and ice, it can be damaged.

To sewage ventilation and heating systems and water supply systems were able to provide a comfortable stay in the house, it is necessary not only to make it the correct installation of your hands, but also at the design stage to foresee all the subtleties and nuances of its operation.

In any case, its installation should be performed only after it is determined the exact number of risers and location of all elements of the sewage.

nuances of designing

When designing sewer ventilation is necessary to pay special attention to the height of its output element.

It should be located as high as possible from ground level, and only then it will be possible to prevent the leakage of water from hydraulic gates, to avoid the formation of air pockets in the system, and to eliminate the possible spread of odors in the interior of the house.

sewer device in a private home is best done with the help of plastic pipes.

Video:

This is due to the fact that the tubes have a relatively small weight, their installation is simple and fast, in addition, they are equipped with all necessary fittings.

Even at the stage of designing the house should be mandatory to include in its design a special air duct, through which the sewer system pipes the output will be carried out.

In that case, if the sewer system of a private house, for whatever reasons, the design did not include the installation of the ventilation ducts, its output can be carried out on the outer wall, while covering its special decorative rosette.

If the construction of the house is carried out in regions with severe climatic conditions, the sewerage ventilation system must necessarily be capable of warming the pipe in order to avoid icing.

Very often it happens that the build quality ventilation of sewage systems, heating and water supply for any reason it is not possible, in this case, a way out could be the installation of a special type of vacuum valve.

Arrangement vacuum valve

Vacuum valves allow you to quickly and effectively equip ventilation for sewage systems, heating and water supply.

Their installation is carried out directly at the end of the sewer riser coming from the house.

This element is a certain size device, which is installed inside a spring having a small resistance.

This valve is leakproof seal that prevents air infiltration.

Video:

In that case, when there is a vacuum in the riser sewer gas, the device is activated and opened, thereby letting the air flow from the corresponding room directly into the system.Further

system pressure is gradually equalized, which leads to the return spring and triggering the closing of the valve, respectively, which thus helps prevent unpleasant odors in the interior of the house from the risers.

course, such vacuum valves can not fully replace a full ventilation of sewage.

The fact is that over time, is their blockage, which is the main cause of their failure.

should also be noted that such device can not prevent the spread of an unpleasant odor when in siphons which are mounted on different plumbing fixtures, the water is completely absent.

course, such valves, in some individual cases, helps eliminate unpleasant odors from the sewage system, however, to completely get rid of the problem, still need a full sewer ventilation.

for the design and installation of a ventilation system should be approached with full responsibility, using only high quality components and materials.

Features ventilation

To sewer ventilation worked fully, it is mandatory to use risers.

should be noted that in the presence of several individual building risers, their best ventilation circuit combined into one.

Normal functioning sewage system in the house depends on the connection to the atmosphere.

only if the pipes are correct venting communication with the outside air space, they will not form air pockets and depression appear that prevent the normal functioning of the whole system.

Video:

It should be remembered that the diameter of the pipe from which the collected sewage ventilation should not be less than the tube diameter of which is assembled directly the sewer standpipe.

The best option to arrange ventilation of the sewage in the house with his own hands - is to provide each individual riser pipe and its separate special deflector.

However, this option is quite expensive, and therefore, is not always available, so most sewer ventilation make common uniting in one single system multiple risers which has one output to the ventilation pipe.

For this purpose, take a pipe with a larger diameter, which will be able to effectively cope with the task and not allow penetration into the interior of the house odors.