Build Daily

Electrics

August 12, 2017 18:05

Wiring in the office

click fraud protection

Depending on the purpose of the premises they use different equipment for placement of cables and electrical control cabinets.Consider an office building equipped with electrical products of the company DKS remont.dkc.ru.

Content

  1. roof area
    1. task
    2. decision
  2. Office.General hall
    1. task
    2. decision
  3. Shielding
    1. task
    2. decision
  4. reception and waiting area
    1. task
    2. decision
  5. Server
    1. task
    2. decision
  6. Kitchen
    1. task
    2. decision

roof area

task

On the roof of the office building is located a large number of cable lines and masts protruding broadcasting network, and power consumers that increase the probability of lightning.That is why from the lightning protection is put back in the office building project.First of all, it is required to withdraw efficiently the grounding lightning current device, and to accomplish this without compromising the equipment installed on the roof and the building itself.

decision

To prevent direct lightning strike in office buildings should be used "Jupiter" system for building an effective lightning protection of buildings.The system includes molniepriemnoe and grounding equipment, wire holders, connectors and mounting accessories.She quickly mounted and has a universal holder for rods 8-10 mm in diameter.System features correspond to RD and CO 34.21.122-87 153-34.21.122-2003 that operate on the territory of Russia.For earthing and protection equipment installed on the flat roof, used molniepriemnye rods.If the equipment is not available, then you need to deploy molniepriemnuyu grid, a step which depends on building protection class.Mesh mounted with universal plastic holders.

omitting fixed on the building facade.The collector is introduced into the ground and using the connector bar-band or band-band connector is attached to the earthing system, which is complemented by vertical grounding for better current spreading in the ground.

Office.General hall

task

open-plan office requires a large space.Organization of artificial lighting in a large size room, subject to normalized electricity consumption parameters is quite a challenge even for the experienced professional.In addition, it is necessary to perform efficient power supply of jobs, given that they are at a distance from the walls.

decision

reduce electricity losses during transmission over long distances is possible using large cross-section of the cable, but it is much more convenient to save energy during the operation, using the lighting busway "Hercules", and use it to cover a large area on the premises.And with the help illuminate the large room, huge energy savings.

Wiring is carried out in the floor screed rendered monolithic corrugated pipes "Octopus", made of HDPE.The pipes are characterized by high mechanical strength and flexibility and allows to perform simple and fast wiring.The lack of fire safety certificate is not a contraindication to the use of pipe for installation in the cement screed, or by pouring in concrete.

In order to ensure power supply of jobs in the open space, use outdoor turret BUS "In-liner Front" system.Turrets can be increased in height that allows you to install them in a large number of EUI.

Shielding

task

shield zone is a small utility room which houses the water-distribution board (Qp).Entering into a shield made of the total power of the riser.Development and design of electrical control area should be performed in accordance with the high requirements of fire safety, because it is the room with the highest possibility of spontaneous combustion.In addition, in a small room it is important to place a compact easy to service equipment.The main reference document in the development of this solution is to GOST 51321.

decision

office Electricity through water-distribution board (Qp) or shield the distribution and accounting of e / e (SCHRU), in which can be installed metering devices and /or silovoeoborudovanie designed to protect power networks.To accommodate silovogooborudovaniya used the ST series hinged metal housing with the circuit board or module for the installation of automatic modular circuit breakers or molded case circuit breaker (MCCB or MCB).When placing equipment for the account of e / e can be used in housing ST with a glass door.ST Series housings are made of metal.They provide a high level of reliability and protection established silovogooborudovaniya and accounting elements of e / e.The high degree of dust and moisture protection ensures long life of power and active equipment in the event of an emergency room paneling.

for emergency lighting or emergency backup power input as possible to use the ST series enclosures with mounting plate.

Fireproof passage to other rooms through the walls and floors are recommended with the help of fire-resistant penetrations system.In places of passage they provide reliable protection against the spread of fire cable routing.The remaining cavities sealed with fireproof sealant DS.It is used in conjunction with fire-resistant cushions DB.For protection from the smoke used flame retardant foam DF.

reception and waiting area

task

an integral part of a modern office are the reception area.The room is equipped with a reception desk administration, on which all information flows.When designing the interior of the reception, it is recommended to divide the space into two functional areas: working and waiting area.Well-designed lighting system in the reception area - a must in any office.It is appropriate to use a decorative lighting, that can be used to illuminate the rack and work surfaces.wiring products are used for lighting control.different groups of fixtures set for decorative lighting.waiting area should provide comfort for visitors, which is realized through the ceiling and wall lights, which should create uniform illumination.

decision

developing a lighting scheme both areas for the construction of electrical networks Group recommended to use flexible corrugated pipes "Octopus".They provide additional insulation of the cable and eliminate the possibility of electric shock if damaged main cable insulation.

Plastic pipes are laid in Stroebe walls, a ceiling and in the floor.You can also put several pipes compactly together and pave the trails of varying configuration.

to power of the working places of the Secretary, equipped to the reception desk at a distance from the walls, used aluminum electric column "In-liner Aero" height of 71 cm. The supply wiring to the column it is advisable to carry out in the corrugated pipe in the floor.The column can be summed electrical cables of different sections, with two opposite sides are mounted wiring accessories series "Viva" and "Brava".The size of the column allows you to set it under the table to hide from prying eyes.

Please note that the wiring accessories can also be used in the waiting area to connect the equipment.There is also EUI optimally installed in aluminum columns.

Server

task

server room is designed for the installation of the server or telecommunications equipment required to complete the work of the office.

In a small room you need to ensure a large number of laying data cables.server room equipment need to be protected from a power outage, unauthorized access and environmental hazards.the required temperature and ventilation is arranged to be installed for the safe and smooth operation of the equipment.

decision

server room equipment should be placed in closed IT-cabinets "RAM telecom".With the help of the universal cabinets DCS intended to install the network, telecom and server equipment, you can configure the system of any complexity.Forced ventilation of the equipment inside the enclosure is provided through a ventilation unit installed on the roof of the enclosure using the system "RAM klima".

All enclosures are equipped with locks that restrict unauthorized access to the equipment and, at the same time providing easy access to his personnel.

of flexible wire tray "F5 Combitech" in the niches of false ceilings, you can easily create a cable track with a lot of twists and branching.Additionally, trays provide natural ventilation of the cable route and prevent overheating.All products marked with the word is applied, which allows to detect and identify the desired cable during installation.Correctly and clearly perform qualitative and professional labeling can use elements of "Quadro" system.

Kitchen

task

presence of the dining area is a prerequisite for the design of the modern office.Kitchen office includes space for cooking or heating food, and dining tables with chairs.To the staff was most comfortable office kitchen is equipped with appliances such as refrigerator, microwave oven, etc.When designing the wiring in this area is necessary to provide electricity on a small area for a large number of power consumers with additional protection from moisture and resistant to dirt.It should be possible to simultaneously and securely connect several appliances.

decision

organize multiple power outlets for connecting home appliances in the kitchen area will help aluminum cable TV series "In-liner Aero".

Shockproof ABAC boxes are used for open wiring and laying of cable lines.They have a protective shielding from electromagnetic radiation, are resistant to the ingress of aggressive action of moisture and possess fire resistance and, moreover, unlike durable plastic, which eventually changes color.

large number of installation products can be installed in sections of cable channels.

Source: remont.dkc.ru