Build Daily

Floor

August 12, 2017 18:06

Warm floor under a laminate with his own hands

warm floor under the laminate coating will make it not only a modern and beautiful, but also functional: you can for a few minutes to create a comfortable indoor climate all year round.Run warm floor under a laminate with his hands quite possible even without expensive technology and concrete screed.

to cover under the laminate required:

  • thermally reflective substrate (IZOSPAN, megaizol and the like);
  • infrared carbon film (with a carbon coating film);
  • Waterproofing foil (PE 160 md)
  • Mounting and electrical adhesive tape;
  • Equipment wire (copper 2.5 mm2);
  • soldering;
  • thermostat and floor sensor.

technology laying of floor heating

warm floor under the laminate your own hands can be installed in any room.to base minimum requirements - it should be smooth, do not have cracks and hillocks.The room must be able to connect to the AC 220V

Stages:

  1. Before laying the floor heating is necessary to clean the rough coating of dirt, debris.It is better to do it with a vacuum cleaner.
  2. Measure the dimensions of the room and make a calculation of the material.Putting infrared film overlap is not allowed.Therefore, if the standard amount of bands do not fit in the width of your room, you can make small gaps between them or put a heating film in the installation of furniture.
  3. thermally reflective substrate when installing underfloor heating under laminate placed throughout the room space.It can be cut if necessary.
  4. glued joints substrate mounting tape on the upper side.
Step 1 - Preparation of a draft surface

Stage 1 - Preparation of a rough surface for laying underfloor heating

  1. The heating infrared film cut-to-size room.Cut it can only be the white areas without disturbing the carbon black layer.
  2. Stack infrared film to the floor over the entire area of ​​the room, free of bulky furniture: wardrobes, furniture walls, massive household appliances.Heat exchange by such furniture is broken and the film may overheat during operation.
  3. Copper busbars to isolate sections of electrical tape, bending it through the incision.We need to make sure that did not get a Scotch air.
  4. ground bus (it is usually in the center of the film and is protected by lamination only) need to bend both sides so that it does not hit the slice and the remaining white areas.
Laying of heating film

Stage 2 -Ukladka heating film

  1. Freed from the copper film portion of the grounding bus isolate electrical tape, pasting it to bend on the wrong side.
  2. film sections were also isolated with tape: Stick it in half width, is folded over the cut.
  3. film are aligned by location and is attached to the substrate on the opposite side from the placement of the thermostat.
  4. Getting soldering wires connecting portions of the film.Film is folded by the controller setting the wrong side up.For convenience, you can temporarily secure it with tape mounting.Prepare equipment wire 2.5 mm2, 50-60 watt soldering iron and solder.With the protective film on the tire edges point-removed insulation.It is convenient to use a hot soldering iron and stationery knife: soldering iron scheduled cutoff edges, melting the insulation and producing a knife trimming.
Works related to the installation of the heating film

work related to the installation of the heating film

  1. film plots are connected in parallel by means of soldering.Stripping insulation from wire installation should be carried out carefully, without incision mine, in an area sufficient for soldering.When connecting the film sections comply with the rule of "phase-zero".The preferred use of the insulated wire with a different color.When soldering is necessary to make sure that the wires are not crossed and were not vnatyag, otherwise it may be damaged or broken.Penetrations through the plinth better put in Corrugated.
  2. solder joints must be insulated electrical tape the size of 5x5 cm.
  3. film placed under a floor sensor, making for him a recess in a substrate heat reflecting knife.The sensor must be placed under the film in the middle of its working area, the warmest point of the room to avoid overheating of the film.The wire bundled with a sensor placed on the substrate and lead towards the temperature regulator.It must be secured to the substrate mounting tape.
  4. wires from the sensor cleaned, ludyat ends and connected to the appropriate terminals on the thermostat.Also, the mounting is connected wire to the heating of the film rails and power cables.
Works associated with soldering wires and connection to the thermostat

works associated with soldering wires and connect to the thermostat

  1. similar supply busses connect the grounding strip of film.For this trimmed from their lamination layer, trimmed if necessary, and connected via wire or copper strip.Wires output is passed through a corrugated pipe.
  2. corrugated insulated at the connection points with the heating tape with electrical tape.
  3. film is fixed on the substrate with a mounting tape, prokleivaya it from all sides.It should ensure that there are no pieces of the heating film overlay on top of each other.
  4. Ground wire output from the corrugated pipe, is attached to the terminal in the thermostat or, in the absence thereof, directly to the grounding circuit.
Soldering wire and ground bus

soldering of the wires and the ground bus

  1. Before laying the finishing coat is necessary to test the functionality of the floor heating.To this end, it is connected to a power supply of 220 V, set the thermostat to the middle position and include heating toggle.Activated briefly, for 1 minute.The heating of all parts of the film is checked by hand.
  2. With the film gently sweep away the remnants of conductive wire and other debris.If necessary, it can be vacuumed.
  3. infrared film for better sealing are covered with plastic wrap to tie-in the wall at 10-20 cm thick polyethylene film -. 160 .mu.m.
  4. film laminate stacked on top of the conventional technology.
system testing and laying laminate

testing system and laying laminate

Infrared warm floor under the laminate - a perfect solution for residential rooms: it perfectly warms, it does not dry the air like conventional radiators, and creates a comfortable indoor climate.

So we put the heat under laminate floor with your hands, but you think it will be useful to read about Radiant floor with their hands, connecting the thermostat to warm the floor, and also about laying cork polazh.

instagram viewer