INTRODUCTION

1. DEVELOPED by the Federal state unitary enterprise - Center for regulation and standardization methods in construction (CNS FSUE) tothe participation of the State unitary Enterprise "Scientific and design Institute of educational, commercial and residential buildings and leisure" (GUP IPH);Central Research and Design Institute of experimental industrial buildings (JSC "TsNIIpromzdany") and a working group of experts

2. INCLUDED Department of technical regulation, standardization and certification in the construction and housing Construction Committee of Russia

3. Adopted and put into effectfrom 1 September 2003, the decision of the State Construction Committee of Russia dated 23.06.2003, № 108

4. INSTEAD SNIP 2.08.02 * (ed. before 2003) in the parts of buildings for research institutes, design and public institutions and buildingsmanagement

INTRODUCTION

This SNP contains rules and regulations for a group of buildings and facilities, with a number of common functional and space-planning features and intended primarily for mental labor and unproductive activities that are different from the buildings to carry out activities for the production of wealthor services to the public.

defining features uniting this group of buildings are part of the main functional groups of rooms, space-planning structure, belonging to the same class as set out in SNIP 21-01 classification of buildings and premises of functional fire hazard by taking into account the method of use of buildings (only during the daytime), the measure of human security threats in case of fire and characterization of the main contingent.

hereto complex set of mandatory regulatory requirements in terms of performance of buildings of institutions and organizations, including and especially their security and compliance with sanitary and epidemiological requirements.

in developing SNP took part: LA Viktorov, PhD.. Architect, N. Polyakov (DSF "Stroysertifikatsiya" at Gosstroy of Russia);A. M. Garnets, PhD.Arch.(GUP "Institute of public buildings");VA Glukharev, SY Sopotsko, PhD.tehn.Sciences (Gosstroy of Russia);I. Lerner, PhD.Arch.(CJSC "CNIIEP them BS Mezentsev.");LA Skrobov, PhD.architect .;TE Storozhenko, PhD.tehn.Sciences (JSC "TsNIIpromzdany"), AV Gomozov (VNIIPO).

building regulations of the Russian Federation

PUBLIC BUILDINGS ADMINISTRATIVE APPOINTMENTS

PUBLIC OFFICE BUILDINGS

Date of introduction 2003-09-01

1 SCOPE

These rules and regulations apply to designand construction of newly built and reconstructed buildings of institutions and organizations, the list of which is given in Appendix E.

the design and construction of buildings and facilities for these institutions, along with the need to apply these rules and regulations and the provisions of other more general regulations, if they do not contradictrequirements of this document.

Standards apply to buildings regardless of whether they are being built at the expense of the federal or municipal budgets, organizations, developers, engaged in the construction of buildings for its own purposes or for subsequent lease.

These rules do not apply to the design of buildings of the Presidential Administration, the State Duma and the Russian Federation, customs;embassies and other facilities of the Ministry of Foreign Affairs of the Russian Federation, located on the territory of other states;public records of the building of laboratory and pilot-production buildings and special facilities of research institutions, as well as office space, placed in mobile buildings.

norms and rules established in the sections of this document:

4. «General Provisions";

6. «Fire safety";

7. «Safety in use";

8. «Ensuring sanitary and epidemiological requirements";

10. «The durability and maintainability," correspond to the objectives of the technical regulation established in the Law "On Technical Regulation", and are required in accordance with paragraph 1 of Article 46.

2 References

In these norms andrules of references to the normative documents listed in Appendix A.

3 tERMS aND dEFINITIONS

this document uses the terms, definitions are listed in annex B, as well as other terms and definitions are taken by the regulatory documents listedin Appendix A. in section 6, "Fire safety" adopted the terms and definitions given in GOST 12.1.033.

4 GENERAL

4.1.Design, construction and reconstruction of buildings must be in accordance with the requirements of these building regulations and other legal documents that establish the rules of design and construction.

4.2.Placement of buildings and structures on the site designated for the building must conform to current legislation, SNIP 2.07.01 and other normative documents for design and construction, as well as architectural and planning tasks and building permits.

4.3.In the design and construction of buildings of institutions should be ensured their accessibility for people with limited mobility, working or visiting the building in accordance with the requirements of SNIP 35-01.These requirements are specified in the design assignment with determination, if necessary, the number of people with disabilities and types of disabilities.

4.4.In the design of institutions placed in the volume of residential building, should, in addition to these rules, guided by the requirements of SNIP 31-01 set for public premises, located in residential buildings.

4.5.The buildings are allowed to provide production and storage facilities required technology institutions and activities included in their composition, which must be reflected in the design assignment.

4.6.Load-bearing structures of buildings must be designed and constructed so that in the process of building and settlement conditions precluded the possibility:

damage or structural damage, leading to the necessity of ending the use of buildings;

unacceptable deterioration of operational properties of structures or buildings in general, due to deformation or cracking.

4.7.Structures and foundations of buildings should be calculated on the perception of these loads and impacts:

constant load of its own weight bearing and protecting designs;

snow load for the construction area;

wind load for the area of ​​construction;

dangerous geophysical impact in the area of ​​construction.

Normative values ​​listed loadings accounted adverse load combinations and their corresponding effort, limiting values ​​of deflections and displacements of structures, as well as the value of the load safety factors have to be taken in accordance with the requirements of SNIP 2.01.07.It must be taken into account as specified in the design assignment additional customer requirements to loads of heavy equipment components.

4.8.Used in the design of structures methods of calculation of the bearing capacity and deformability to meet the requirements of existing regulations on the design of appropriate materials.

When placing buildings on undermined territories, on subsiding soils in seismic regions, as well as other complex geological conditions, additional requirements of the relevant rules and regulations should be considered.

4.9.Foundations of buildings must be designed taking into account the physical and mechanical properties of soils, provided for in the SNIP 2.02.01 (for permafrost - in SNIP 02/02/04), the characteristics of the hydrogeological regime of on-site construction, as well as the degree of aggressiveness of soil and groundwater in relation to foundationsand underground utility networks and the need to ensure the uniformity and minimum speed pellet bases under the elements of the building.

4.10.For buildings and premises of institutions should include a system of hot and cold water supply, sewerage, drains, fire line, in accordance with SNIP 2.04.01.

Eyeliner hot water should be provided to the process equipment dining rooms and buffets to standpipes sinks in the inventory, cleaning rooms, washing your hands in the health centers and health units, to instruments cabins women's personal hygiene and to other devices on the design assignment.

4.11.Heating, ventilation and air conditioning of buildings, as well as smoke extraction in case of fire must be designed in accordance with SNiP 41-01 and the requirements of sections 7 - 9 of this document.

on the input of heat networks in the building should provide heat points (CTP and ITP).

4.12.In buildings, institutions should provide electrical, lighting, city telecommunication devices, wire broadcasting and television, fire and burglar alarm system fire alarm (according to the airbag 104), signaling devices gas pollution, smoke and flood, automation and control engineering equipment systembuildings, as well as a comprehensive network of elektroslabotochnuyu.

in accordance with specific requirements established in the job for designing, building complexes, separate buildings or rooms equipped with the devices of the local (internal), telephone, local units of wire broadcasting and television, sound systems, amplification and simultaneous interpretation of speech, time, alarm settings.

4.13.Electrical devices of buildings should be designed in accordance with the EMP and other applicable rules and regulations, duly approved.

4.14.Lightning protection of buildings should be carried out taking into account the availability of television antennas and tubal holders telephone network or a wired network broadcasting in accordance with the RD 34.21.122 Regulations.

4.15.Gas supply systems of buildings of institutions should be designed in accordance with SNiP 42-01 and safety rules in the gas sector.

4.16.In buildings, institutions should provide a purification system from debris and dust cleaning.The need chutes devices establish the design assignment.For buildings not equipped with refuse chutes, should provide the collecting chamber or economic area.

debris removal means of the building must be linked to the treatment system adopted in the locality where the building is placed.

4.17.Passenger lifts should be provided in the buildings of institutions at the difference floor marks the lobby and upper floors of 12 m or more;in the buildings of institutions, constantly visited by the population, with a difference of elevations 9 m and more;if there is on the second floor and above rooms intended for disabled people, - in accordance with SNIP 35-01.

distance from the doors of the remote room to the door of the nearest passenger lift should not exceed 60 m.

Necessity device other means of vertical transportation in buildings of institutions established by the design assignment.

number of passenger elevators should be installed by calculation, but not less than two, with one of the elevators in the building (passenger or cargo and passenger) must have a minimum depth of the cabin 2100 mm for human transport capabilities on a stretcher.

4.18.Upon request, the developer of the documentation for the building should further include instructions for use.It should contain requirements and conditions necessary to ensure the safety of buildings and structures in service, including information about the basic design and engineering systems layout hidden items frame, hidden wirings and utilities, as well as the limits loads on the elements of the building designsand its grid.These data can be presented in the form of copies executive documentation.

5 REQUIREMENTS FOR ACCOMMODATION

5.1.The rooms in the buildings for administrative purposes, as a rule, consists of the following basic functionalities:

a) Senior Management;

b) working premises of structural units of institutions and organizations;

c) facilities for meetings and (or) conference facilities;

g) placing information and technical purposes, including: technical libraries, design offices, archives, facilities information and computer technology, etc. depending on the design assignment;.

d) entrance facilities, including: lobby, avanvestibyul, wardrobe, pass office, security room;

e) the premises of welfare services, including catering facilities, medical care, sanitary, household premises for maintenance and operating personnel, sports and recreation facilities, etc .;

g) the maintenance of the building space, including repair shops, storage rooms for various purposes, etc .;

h) facilities for technical equipment, including ventilation chamber, switchboard, etc.

5.2.The composition of the rooms, their area and functional relationship in the buildings of institutions defined by the customer in the design assignment and (or) in accordance with the calculated guidelines that are outlined in Appendix A, or sets of rules for the design of different types of buildings.The composition of the premises of the functional groups and the - g and g in the institutions established in the design assignment, and their area is determined by the departmental or technological standards, it should be borne in mind that one employee on the premises of the functional group used shall be at least 6 m2 excluding the area,designed to accommodate orgtehosnastki.The composition, equipment, including the number and area of ​​the premises santehpriborov functional groups d and e are determined by the norms established in the SNIP SNIP 2.08.02 and 09.02.04.

5.3.Composition and floor space for means of information and computer technology and communication, as well as requirements to them are determined by specific terms of reference annexed to the design assignment.

5.4.The composition and area of ​​specialized premises of buildings of financial institutions, banks, judicial and legal and other institutions are defined in the design assignment in view of departmental regulations and (or) codes of practice.

5.5.The height of the rooms from floor to ceiling should be at least 3 m. In the small office to be placed in the volume of residential buildings, offices and factory is located in the administrative and residential buildings, premises height may correspond height adopted in these buildings.

5.6.The height of the corridors and hallways should be at least 2.4 m;. In offices, located in residential buildings, offices and factory is located in the administrative and residential buildings - at least 2.2 m

corridor width should be no less than 1.2 m at a length of 10 m;not less than 1.5 m - length of more than 10 m and not less than 2.4 m - using them as lobbies or waiting rooms for visitors.

5.7.Height technical floors should be made taking into account the equipment is located, utility networks and their operating conditions;while in traffic areas attendants height in purity should be at least 1.8 m.

5.8.Through passages in buildings should take a clear width of not less than 3.5 m, a height of not less than 4.25 m. Through the passages through the stairwells of buildings should be located at a distance from each other of not more than 100 m.